top of page

BVG Nuclear Private Limited (BVGNPL) is a new addition to the BVG family. A start-up with blend of path breaking technology and team of dedicated expertise, the company is poised to undertake detection of leakages and complex defects in refinery columns, heat exchangers, underground pipelines, dams, reservoirs etc. using advance radiation techniques.
Repairs of dams, guided dredging and ash disposal are other forte of BVGNPL.
The applications developed by the company not only benefits the proprietor in terms of saving the money, time and efforts but helps the society and environment as well.

Vision

Serve the humanity and the nature with application of non-destructive state of art detection and analysis technology 

BVG Nuclear

Our Services

1. Blockage Detection

Present Scenario

Present Technique-Hydro-testing of the pipelines only indicates the presence of leak but not the specific location

  • Limitations in Existing Technique:-

  1. No accuracy

  2. Time consuming

  3. Very costly

Applications

  • To exactly pinpoint the location of leakage

 

Advantages

  • High Detection Sensitivity

  • Unambiguous

  • Pinpoint Detection of Problem Area

  • Faster Method of Detection and Analysis

  • Cost Effective

  • Protects Environment

Technology Offered

  • Identification of leakage location in underground Pipelines

EFF24E6E-E456-43C9-A941-3D801313614E.jpeg

2. Heat Exchanger Leakage Detection

Present Scenerio

Present Technique-Shut down and visual inspection

  • Limitations in Existing Technique:-

  1. Time consuming

  2. Very costly which involves huge loss due to process shutdown.

Applications

To identify the leaking heat exchanger from the heat exchanger series

Advantages

  1. Online Technology, No Requirement of Process Shutdown

  2. Huge Savings on Shutdown Costs

  3. Faster method of Detection and Analysis

  4. Preparation for Detection Process can be Undertaken without Disturbing Plant Operations

  5. Cost Effective

0B7E3825-62DD-4E81-9F7A-65702C931CB5.jpeg

3. Sediment Transport Study

Present Scenario

Present Technique-Rough understanding based on scaled down mathematical models of the ports

  • Limitations in Existing Technique:-

  1. No accuracy

  2. Time consuming

  3. Very costly

Applications

To propose suitable site for disposal of dredged sediments from navigation channel of the port
Ports stand to advantage as sediments deposited at selected locations will not spill back into to the navigation channel
Suitable location for sediment disposal can be accurately selected as close as feasible which would result in huge saving of dredging costs

Advantages

  • High Detection Sensitivity

  • Unambiguous

  • Cost Effective

D2128259-700C-436B-B962-3E9E0074E756.png

4. Pipe Scanning

Present Scenario

  • No technology available to correctly assess the exact location and nature of blockage

  • The entire pipeline requires to be closed for operation which results in heavy revenue losses

  • Vey time consuming

  • Present method require heavy manpower and transportation for removal and shifting of liquid in affected pipeline at the time of repairs

Applications

Investigate presence of blockage, its specific location and its extent both in underground and over-ground pipelines.

Advantages

  • High Detection Sensitivity

  • Unambiguous

  • Pinpoint Detection of Problem Area

  • Faster Method of Detection and Analysis

  • Cost Effective

  • Protects Environment

E550A470-52BE-46E7-871B-3CCD7EC02938_4_5005_c.jpeg

5. Leakage Detection From Reservoirs

Present Scenario

Present Technique-Visual inspection to assess leakage

Grouting carried out not in conformity with leakage location.

  • Limitations in Existing Technique:-

  1. No accuracy

  2. Time consuming

  3. Unnecessary heavy expenditure without confirming exact location of the leakage source

  4. Very costly

Applications
  • To pinpoint location of leakage in dams

  • On confirmation of the exact location, the same can be arrested by specific grouting (services provided by BVG) which will result in considerable cost saving and loss of water.

Advantages

  • Accurate Pinpointing of Leakage

  • Results in saving of Water which would otherwise have wasted due to non detection of leakage source in time.

  • Faster method of Detection and Analysis

  • Cost Effective

859C58E2-3216-4E39-848F-2EFCBDB616A5.png
460DEAF2-049D-4D2C-A723-D091CEA86CBA.jpeg

6. Fly Ash Disposal Studies

Present Scenario

Present Technique-Visual inspection to assess leakage

Grouting carried out not in conformity with leakage location.

  • Limitations in Existing Technique:-

  1. No accuracy

  2. Present Technique-Analysis of geo hydrological parameters

  3. Limitations in Existing Technique:-

  4. No accuracy

  5. Time consuming

  6. Ambiguous

15A316D1-CAD7-49A8-B948-02399057289A.jpeg
  • Technology Offered
  • Best way to get rid of fly ash from thermal power plants is to dispose it as slurry in to a mine void

  • Radiotracer (46Sc) is used to study its environmental impact

  • Applications

  • Investigate leaching of heavy elements contained in fly ash into the ground water

  • Study contamination of pond water

  • Advantages

  • High Detection Sensitivity

  • Unambiguous

  • Pinpoint Detection of Problem areas

  • Faster method of Detection and Analysis

  • Cost Effective

  • Protects Environment

9FAF3C64-748E-4557-9C5C-BDA57DEA0F48.jpeg

7. Gamma Column Scanning

Present Scenario

Operational parameters are checked by visual inspection and analysis

  • Limitations in Existing Technique:-

  1. No accuracy

  2. Offline technique

  3. Requires total plant shut down

  4. Heavy time penalty

  5. Post damage technology and no scope for preventative maintenance

  6. Huge revenue losses

0A7D3413-10B3-429F-ABEC-C42CC94BAFB6.jpeg

Advantages

  • Can be used for preventative as well as post damage investigation

  • Online Technique- No Requirement of shutdown

  • Cost Effective

  • Pinpoint Detection of Problem areas

  • Faster method of Detection & Analysis

Applications

 

  • Assesses hydraulic performance using relative density differences

  • Debottleneck columns and units

  • Monitors response to operating changes

  • Pre-turnaround detection of tray and packing replacements

  • Verifies placement of trays, packed beds and distributors

  • Evaluates the quality of liquid phase distribution

  • Evaluates tray froth heights

  • Detects mechanical, rate and process related problems

  • Detects fouled / crushed packing, overflowing distributor and collector trays, flooding foaming or vapour induced maldistribution

  • Evaluate tray froth heights

9B25CE91-B71F-4D68-9332-4FBAD5AAC8D9_4_5005_c.jpeg
2643CCCE-7A30-429B-8D3A-1DAD963516D0.jpeg
0CC9AAF8-AC3F-4499-8E4D-9913A4901B99.jpeg

For More Information Visit

7853B894-7F0F-4958-AE52-399C76C94081.png
bottom of page